Reliability Test Terms for Hall elements

HW-series

Test
N
Conditions
Standard
Time
High Humidity Storage Test
22
Ta = 85°C, RH = 85%
Within +-20% of the initial value.
Note; | Vos |<=(Upper standard limit +5mV)
1000hrs
High Temperature Bias Test
22
Ta=110°C Ic is the bias current
Same as above
1000hrs
Heat-Proof Test for Soldering
22
Dipped in the 260+-5°C
solder up to the 1mm part from the body.
Same as above
10+-1sec
High Temperature Storage Test
22
Ta=125°C
Same as above
1000hrs
Heat Cycles Test
22
-40°C =>> Room
Temperature
=>> +125°C
30min <<= 5min <<= 30min
Same as above
50 cycles

HG,HZ,HQ-series

Test Item
N
Test Condition
Standard
Test Time
High Humidity Storage Test
22
Ta=85°C, RH = 85%
Within +-20% of the initial value.
Note; | Vos |<=(Upper standard limit +5mV)
1000hrs
High Temperature Bias Test
22
Ta=125°C
Ic is the bias current
Same as above
1000hrs
Heat-Proof Test for Soldering
22
Dipped in the 300+-5°C
solder up to the 1mm part from the body.
Same as above
5+-2 sec
High Temperature Storage Test
22
Ta=150°C
Same as above
1000hrs
Heat Cycles Test
22
-55°C =>> Room Temperature =>> +150°C
30min <<= 5min <<= 30min
Same as above
50 cycles